Drive to improve flash reliability
Due to its limited write cycles, flash-based storage can corrupt data. Computer Weekly looks at how flash reliability is being addressed
Solid-state drive (SSD) flash memory storage devices have accelerated laptops and server-based computing. As organisations embark on digital transformation and look to use techniques such as artificial intelligence (AI) to provide greater insight into the data they collect, there is demand not only for more storage, but increasingly fast data access.
For example, Total Gas & Power sees an opportunity to deploy flash-based storage to accelerate on-premise applications that need to integrate with cloud services. Total Gas & Power has deployed Nutanix hyperconverged infrastructure, and has also been replacing its NetApp filer with a flash-based storage array,
“We have got into integration in a big way,” says Dominic Maidment, technology architect at Total Gas & Power. The company is using MuleSoft to manage its application programming interfaces and is looking at how flash can power hybrid integration. “With on-premise data assets, access has to be as fast and as light as possible,” says Maidment.
Revolution of storage
Enterprise storage used to be synonymous with vast arrays of hard disks, made from a platter of disks spinning at thousands of revolutions per minute, each with a disk head floating just a few micrometres above. If the head crashes into the disk, data loss can occur. Flash SSDs that use Nand memory chips got rid of the spinning disks, so they should be more reliable. Right?
The problem is that although flash-based storage has extremely high levels of reliability, it is still prone to data loss and requires a host of measures to keep data uncorrupted. In flash SSDs, data is stored in blocks of memory, which are written to the SSD device as 4KB pages. Data is erased in 256KB blocks. So far, so good. But back in 2008, a study by Jet Propulsion Labs (JPL) said flash storage produced higher error rates when the same block of memory was continuously cycled with data being written to it, then erased.
Ben Gitenstein, vice-president of product management at data storage company Qumulo, says this means flash drive sectors become unusable after a certain number of overwrites. As a result, flash-based storage devices can be written to only so many times before “wearing out”.
The 2008 JPL study found that many systems implement wear-levelling, in which the system moves often-changed data from one block to another to prevent any one block from getting far more cycles than others.
Beyond dynamic management of flash drive data blocks, the IT industry has tended to over-provision the number of flash drives required to allow for dynamic reallocation of bad sectors. In large datacentre facilities, routine maintenance requires replacing drives on a regular basis to reduce errors and bad chips.
In 2016, researchers looking at the use of flash drives in datacentres warned that during the majority of days that a flash drive is operational (drive days), at least one correctable error will occur.
However, the researchers reported that other types of transparent errors, which the drive can mask from the user, are rare compared with non-transparent errors.
The results of the study into the reliability of flash storage in a datacentre environment were presented at the 14th Usenix Conference on File and Storage Technologies (Fast ’16) in Santa Clara by Bianca Schroeder, associate professor at the University of Toronto, and Google engineers Raghav Lagisetty and Arif Merchant.
The study, which assessed six years of flash storage reliability in Google’s datacentres, reported that compared with traditional hard disk drives, flash drives have a significantly lower replacement rate in the field. However, they have a higher rate of uncorrectable errors.
The research looked at reads and writes of the same data across a range of flash drives, covering different generations of flash technology. All the systems tested used the same error correction code. The study found the most common errors were read errors that could not be resolved even after retrying the operation. These are called non-transparent errors.
According to the research paper, write errors rarely turn into non-transparent errors. “Depending on the model, 1.5- 2.5% of drives and one to four out of 10,000 drive days experience a final write error – a failed write operation that did not succeed even after retries,” said the paper.
The researchers surmised that the difference in the frequency of final read and final write errors is probably due to the fact that a failed write will be retried at other drive locations. The report stated: “So while a failed read might be caused by only a few unreliable cells on the page to be read, a final write error indicates a larger-scale hardware problem.”
The study found that up to 80% of drives developed bad data blocks and 2-7% of the drives tested developed bad Nand memory chips during the first four years of their life. These, according to the researchers, are drives that, without mechanisms for mapping out bad chips, would require repairs or to be returned to the manufacturer.
Advanced practices mean that SSDs are good for five years or more
Originally, Nand flash was laid out in a plane, with each cell supporting two levels or a single bit, writes Alex McDonald, chair, SNIA EMEA. This is a single-level cell (SLC). Now we have progressed through MLC (four levels and two bits), through TLC (eight levels and three bits) up to 16 levels and four bits per cell (QLC), and improved densities by “building up” with a 3D stack of cells.
The unit of write is not a single cell, but a page of cells of around 4KB. At a higher level, several tens of pages are organised into blocks. Prior to writing to pages, a block needs to be erased in preparation – program/erase (P/E) cycles. There are only so many P/E cycles that the flash can tolerate before failing.
The advantages of QLC and 3D-based technology is their ability to build very high-density devices, with 32TB devices relatively commonplace. Generally, with more bits per cell, fewer P/E cycles can be performed. Interestingly, these limitations have not necessarily reduced the practical reliability of high-density Nand flash SSDs, because there are many techniques that are used to mitigate the possibly unreliable operation of single cells.
Practices such as error correction code (ECC); significant overprovisioning of the Nand to allow for wear failure by automatic remapping of pages; and a range of techniques that spread the writes over all the pages in a more even fashion to prevent asymmetric wear are employed. All of these can be managed by the drive firmware itself without external intervention.
These advances mean that manufacturers are now in the position to support solid-state drive (SSD) lifetimes of five years or more, with the equivalent of many drives’ worth of data writes per day before the device wears out, even for QLC devices. In enterprise environments, the SSD’s key characteristics of high read and write bandwidths, support for very high input/output operations per second (IOPS) and lower power consumption, make them very attractive for heavy input/output workloads.
When they looked at the symptoms that led to the chip being marked as failed, across all models, about two-thirds of bad chips were declared bad after reaching the 5% threshold on bad blocks. Interestingly, at the time of the study, the researchers noted that the bad chips that saw more than 5% of their blocks fail were chips that had actually violated manufacturer specifications.
The study’s conclusion was that between 20% and 63% of drives experience at least one uncorrectable error during their first four years in the field, making uncorrectable errors the most common non-transparent error in these drives.
A year before the study on Google’s datacentres, researchers from Carnegie Mellon University and Facebook looked into the reliability of flash-based SSDs. This study reported that the more data that is transmitted over the computer’s PCI-Express (PCIe) bus, to and from the flash storage device, the greater the power used on the bus, and the higher the SSD temperature. The study found that higher temperatures lead to increased failure rates, but do so most noticeably for SSDs that do not employ throttling techniques that reduce data rates.
More recently, the 2018 paper The errors in flash-memory-based solid-state drives: analysis, mitigation, and recovery from Seagate Technology, Carnegie Mellon University and ETH Zurich, highlighted the fact that higher storage density leads to higher error rates and failures.
“As the underlying Nand flash memory within SSDs scales to increase storage density, we find that the rate at which raw bit errors occur in the memory increases significantly, which in turn reduces the lifetime of the SSD,” the researchers warned.
Undoubtedly, SSDs are more reliable than traditional enterprise disk arrays. “Traditionally, if you wanted to replace an enterprise hard drive in a disk array, it required a £5,000-a-day engineer to come on site to remap the array with the new drive,” says Rob Tribe, senior systems engineering director at Nutanix.
Read more about Flash Storage
Nottingham Building Society ditches geriatric IBM storage array to gain reliability, boost capacity by 20 times and make energy savings with Nexsan, but rejects flash storage for spinning disk SAN.
Companies of all sizes are turning to all-flash storage arrays to meet their storage capacity, performance, reliability and data protection requirements.
He says the firmware in SSD drives constantly looks at the write cycle, and when it finds failures, it fences off blocks of memory that are producing too many errors. As IT becomes more automated, Tribe acknowledges that the metrics the SSD firmware provides are not yet being fully utilised by operating system software.
Reliability is measured by failed input-output operations – read and writes to the drive. But, going forward, SSD firmware could be used in the future to carry out preventative maintenance, in which the system itself can closely track and monitor how the SSD wears.